1 | PIR Ready VTR7300 Series-Installation Guide
CONTENTS
Installation 2
Location 2
Installation 2
Operation Overview 3
Model Chart 5
Network ready 6
Terminal, Identification and Function 6
Communication wiring to VC3xxxX Relay Pack 6
Network wiring topology 7
VC3xxx LED Operation 7
Wiring of local inputs to VTR73xxA Terminal Equipment Controller 8
Configuring and Status Display Instructions 8
Status display 8
User Interface 10
Local keypad interface 10
Dual occupied setpoints adjustment 11
Single occupied setpoints adjustment 11
Unoccupied and stand-by setpoints adjustments 11
Mode button menu sequence. 11
Installer Configuration Parameter Menu 12
Configuration interface 13
PIR Ready VTR7300 Series
Terminal Equipment Controller
Installation Guide
For Commercial and Lodging HVAC
Fan Coil Applications
May 3
rd
, 2012 / 028-0298-R8
Przeglądanie stron 0
1 2 3 4 5 6 ... 24 25

Podsumowanie treści

Strona 1 - Installation Guide

1 | PIR Ready VTR7300 Series-Installation Guide CONTENTS Installation 2 Location 2 Installation 2 Operation Overview 3 Model Chart 5 Netw

Strona 2 - INSTALLATION

10 | PIR Ready VTR7300 Series-Installation Guide USER INTERFACE Unoccupied mode override An Override can be made on commercial models d

Strona 3 - OPERATION OVERVIEW

11 | PIR Ready VTR7300 Series-Installation Guide Dual occupied setpoints adjustment (Local occupied setpoint adjustment when “Stp Func” = Dual Stp)

Strona 4

12 | PIR Ready VTR7300 Series-Installation Guide AutoMode set to OFF = Auto system mode NOT ACTIVE SEQUENCE SELECTED MODE MENU 0 = Cooling Only Off

Strona 5 - MODEL CHART

13 | PIR Ready VTR7300 Series-Installation Guide access to all configuration properties of the Terminal Equipment Controller. Entering a wrong passwo

Strona 6 - Network ready

14 | PIR Ready VTR7300 Series-Installation Guide PAN ID Personal Area Network Identification Default value = 0 Range is: 0 to 1000 Conditional p

Strona 7 - VC3XXX LED OPERATION

15 | PIR Ready VTR7300 Series-Installation Guide Get From Terminal Equipment Controller Get From another device configuration utility Default value

Strona 8 - Status display

16 | PIR Ready VTR7300 Series-Installation Guide BI 2 Binary input no.2 configuration Default value = None (None): No function will be associated w

Strona 9

17 | PIR Ready VTR7300 Series-Installation Guide RUI 1 Cont’d  Contact opened = No alarm  Contact closed = Alarm displayed (Service): A backl

Strona 10 - USER INTERFACE

18 | PIR Ready VTR7300 Series-Installation Guide %RH disp Local %RH Display Default value = Off Models with Humidity sensor only Conditional param

Strona 11

19 | PIR Ready VTR7300 Series-Installation Guide SeqOpera Sequence of operation Default is: Sequence #1 Selects the initial sequence of operation re

Strona 12

2 | PIR Ready VTR7300 Series-Installation Guide INSTALLATION Remove the security screw on the bottom of Terminal Equipment Controller cover. 

Strona 13 - Configuration interface

20 | PIR Ready VTR7300 Series-Installation Guide %RH set Dehumidification setpoint Default is 50 % RH Conditional parameter to Humidity models VTR

Strona 14

21 | PIR Ready VTR7300 Series-Installation Guide Unocc HT Unoccupied heating setpoint Default value = 62 °F Unoccupied heating setpoint range is

Strona 15

22 | PIR Ready VTR7300 Series-Installation Guide Set Type Temporary setpoint enable Default is : Permnent Enables temporary setpoints feature to a

Strona 16

23 | PIR Ready VTR7300 Series-Installation Guide Auto Fan Auto Fan Function Default value: AS Auto Speed Fan Mode operation for Fan Sequences 2

Strona 17

24 | PIR Ready VTR7300 Series-Installation Guide SPECIFICATIONS Terminal Equipment Controller power requirements: Operating conditions: Storage co

Strona 18

25 | PIR Ready VTR7300 Series-Installation Guide DRAWING & DIMENSIONS Viconics Technologies Inc. Tel.: Fax: Toll free:w

Strona 19 - SYSTEM = 4 PIPES

3 | PIR Ready VTR7300 Series-Installation Guide 12. Re-Install wiring terminals in their correct locations (fig. 3). 13. Re-install the cover (top

Strona 20

4 | PIR Ready VTR7300 Series-Installation Guide 2 or 4 pipe only with electric reheat can be configured and wired for the following: o Cooling onl

Strona 21

5 | PIR Ready VTR7300 Series-Installation Guide MODEL CHART

Strona 22 - 0.0 °F or °C

6 | PIR Ready VTR7300 Series-Installation Guide Network ready  All Viconics VTR7300 series Terminal Equipment Controllers are designed for stand-al

Strona 23

7 | PIR Ready VTR7300 Series-Installation Guide From the VTR73xxA to the first VC3xxxX Relay Pack  Uses existing or new field wires  A minimum o

Strona 24 - PECIFICATIONS

8 | PIR Ready VTR7300 Series-Installation Guide Wiring of local inputs to VTR73xxA Terminal Equipment Controller CONFIGURING AND STATUS DISPLA

Strona 25 - DRAWING & DIMENSIONS

9 | PIR Ready VTR7300 Series-Installation Guide % RH display is conditional to: (Humidity display is model and configuration dependent)  Model with

Komentarze do niniejszej Instrukcji